SUNCOMBE CIP and Hygienic Processing Excellence since 1961
Highlights FreeStyle Menus Demonstration  

Industry Focus

 

 

Product Focus

 

Project Focus

Early in 2007 Allergy Therapeutics PLC (ATp) launched a project to upgrade one of their manufacturing processes for the treatment of allergies. Suncombe were awarded the contract for the detailed design and build of the 8 preassembled units that comprised the process. 

Rick Poland - UK Manufacturing Engineering Manager - 10th December 2007

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 
Technology > CIP Flowrates
 
 
 

CIP Flowrates 
Volume per unit length in hygienic tubing
Tube OD (in) Tube OD (mm) Volume per metre length (ltr)
0.5 12.7 0.07
0.75 19 0.25  
1 25.4 0.39
1.5 38.1 0.89  
2.0 50.8 1.63
2.5 63.5 2.82  
3.0 78.2 4
4.0 101.6 7.6  
6.0 152.4 18.2
8.0 203.2 31  
10.0 254 49
12.0 304.8 70  
Flowrate to achieve recommended cleaning velocity of 1.52 m/sec (5ft/sec) in hygienic tubing
Tube OD (in) Tube OD (mm) Flowrate in ltrs/minute Flowrate in ltrs/hr
0.5 12.7 6.5 390
0.75 19 18 1080
1 25.4 35 2100
1.5 38.1 90 5400
2.0 50.8 162 9720
2.5 63.5 257 15420
3.0 78.2 386 23160
4.0 Contact Suncombe
6.0 Contact Suncombe
8.0 Contact Suncombe
10.0 Contact Suncombe
12.0 Contact Suncombe